The core of the AO denitrification process is the sequential operation of two stages: anoxic and aerobic. Nitrogen conversion and removal are achieved through the synergistic action of microorganisms. The specific process can be divided into three steps:
: In the anoxic stage (A tank, DO <= 0.2 mg/L), heterotrophic bacteria convert nitrogen from organic pollutants, such as proteins and fats in the wastewater, into ammonia nitrogen (NH₃-N).
: In the aerobic stage (O tank, DO=2–4 mg/L), nitrifying bacteria, under sufficient oxygen supply, oxidize ammonia nitrogen into nitrate nitrogen (NO₃⁻) or nitrite nitrogen (NO₂⁻).
: The nitrified liquid from the aerobic stage is returned to the anoxic stage via internal recirculation. Denitrifying bacteria, under anoxic conditions, reduce nitrate nitrogen to nitrogen gas (N₂), which is then released from the water body through aeration, completing the denitrification loop. This process design offers two major advantages:
First, with the anoxic tank preceding the aerobic tank, organic carbon in the wastewater can be directly utilized by denitrifying bacteria, reducing both the organic load on the aerobic tank and the cost of external carbon sources.
Second, the alkalinity generated by denitrification compensates for the alkalinity consumed by nitrification in the aerobic tank, helping to maintain system pH stability.
However, the AO process also has significant drawbacks: its nitrogen removal efficiency is not high, typically only 70–80%, far lower than the 90–95% removal rate for organic matter. Nevertheless, for most conventional wastewater projects, controlling key parameters can significantly improve nitrogen removal efficiency. For high-ammonia-nitrogen wastewater, a two-stage AO series design is typically sufficient.
: The MLSS concentration directly affects the number of nitrifying and denitrifying bacteria. It is recommended to maintain it above 3,000 mg/L; below this value, the system's nitrogen removal capacity will significantly decrease.
: Nitrifying bacteria are "slow-growing bacteria." If the organic load is too high, heterotrophic bacteria will multiply rapidly, competing for oxygen and nutrients. It is recommended to control the sludge loading rate to less than 0.10–0.15 kgCOD/kgMLSS·d. This can be achieved by increasing the MLSS concentration or increasing the aeration tank volume, reducing the organic load, and providing sufficient space for nitrifying bacteria to proliferate.
: The minimum specific growth rate of nitrifying bacteria is only 0.21/d, far lower than the 1.2/d of heterotrophic bacteria. To allow nitrifying bacteria to become the dominant species, the sludge age must be greater than 4.76 days. However, the sludge age of traditional activated sludge processes is only 2–4 days, which is a core reason why nitrification cannot be completed.
: The ammonia nitrogen load (organic nitrogen + ammonia nitrogen) for nitrification needs to be controlled below 0.05 gTKN/(gMLSS·d). Excessive load will exceed the treatment capacity of nitrifying bacteria, leading to ammonia nitrogen accumulation and interruption of denitrification.
: If the influent BOD₅ concentration is too high (exceeding 80 mg/L), heterotrophic bacteria will proliferate, competing with nitrifying bacteria for oxygen, thus inhibiting nitrification. Therefore, the BOD₅ entering the nitrification tank needs to be controlled below 80 mg/L.
: To ensure complete denitrification, the C/N ratio must be controlled between 4 and 6. If the carbon source is insufficient, denitrification cannot proceed completely, and nitrate nitrogen will remain, resulting in a high total nitrogen concentration in the effluent.
: The effect of ammonia nitrogen concentration on nitrification shows a "rise then fall" trend. At low concentrations, the reaction rate increases with increasing concentration. However, when the ammonia nitrogen concentration at the front end of the aerobic tank in municipal wastewater exceeds 100 mg/L, and in industrial wastewater exceeds 150 mg/L, nitrification will be inhibited. For high-ammonia-nitrogen wastewater (such as aquaculture wastewater and landfill leachate), the initial influent concentration can be reduced through recirculation dilution.
: A higher recirculation ratio results in a higher denitrification rate, but also increases electricity costs. It is typically controlled between 300–500%, and can be fine-tuned based on the effluent total nitrogen data. If the total nitrogen is high, the recirculation ratio can be appropriately increased. If operating costs are too high, it can be reduced while still meeting standards.
: Nitrifying bacteria are "aerobic bacteria," and sufficient oxygen is a prerequisite for nitrification. It is recommended to maintain DO between 2 and 4 mg/L. Theoretically, oxidizing 1 g of NH₄⁺ requires 4.57 g of oxygen. If DO falls below 2 mg/L, the nitrification reaction will slow down significantly.
: Sufficient retention time is essential for a complete reaction. The HRT for nitrification should be greater than 6 hours, and for denitrification, it should be 2 hours, with a ratio of 3:1. Otherwise, nitrogen removal efficiency will drop rapidly.
: The optimal pH for nitrifying bacteria is 8.0–8.4, and for denitrifying bacteria, it is 6.5–7.5. pH deviations from these ranges will severely affect microbial activity. Furthermore, the complete nitrification of 1 g of ammonia nitrogen requires 7.1 g of alkalinity (calculated as CaCO₃), while the alkalinity produced by denitrification can compensate for about half. If alkalinity is insufficient, it needs to be replenished promptly (e.g., by adding sodium carbonate) to prevent pH drop and inhibition of nitrification.
: Temperature directly affects microbial activity. The optimal temperature for nitrification is 20–30℃, and it almost stops below 5℃. The optimal temperature for denitrification is 20–40℃, and the rate drops rapidly below 15℃. During winter operation and maintenance, denitrification rates need to be maintained by increasing sludge age, reducing load, and extending hydraulic retention time.
: Excessive salinity damages microbial cell membranes and affects oxygen transfer, thus inhibiting nitrification. Under normal conditions, nitrification can proceed normally when the chlorine concentration is less than 2,000 mg/L. If the influent is stable, salt-tolerant bacteria can be cultivated to allow operation even at a chlorine concentration of 5,000 mg/L. Note: Fluctuations in salinity are more dangerous than high salinity, as they can easily lead to sludge loss.
: Heavy metals, phenols, thiourea, free ammonia, antibiotics, etc., can directly kill nitrifying bacteria or inhibit their enzyme activity. When treating wastewater containing these substances, pretreatment (such as coagulation, sedimentation, and adsorption) is essential, and the introduction of toxic and harmful substances into the biological treatment tank should be strictly prohibited.
You can browse other products on our website. Please contact us if you have any questions. We hope this information is helpful for your wastewater treatment.